A Simple Positron Emission Tomography-Based Calibration for Perfusion-Weighted Magnetic Resonance Maps to Optimize Penumbral Flow Detection in Acute Stroke.

BACKGROUND AND PURPOSE: Perfusion-weighted (PW) MRI is increasingly used to identify the tissue at risk. The adequate PW-MRI map and threshold remain controversial due to a considerable individual variation of values. By comparative positron emission tomography, we evaluated a simple MR-based and positron emission tomography-validated calibration of PW maps.

METHODS: PW-MRI and quantitative positron emission tomography (15O-water) of patients with acute stroke were used to calculate averaged as well as individual thresholds of penumbral flow (positron emission tomography cerebral blood flow (<20 mL/100 g/min) for maps of time to peak, mean transit time, cerebral blood flow, and cerebral blood volume. A linear regression analysis studied the variability of the individual thresholds using 3 different PW reference regions (hemispheric, white matter, gray matter). The best model was used for volumetric analysis to compare averaged and scaled individual thresholds and to calculate look-up tables for PW maps.

RESULTS: In 26 patients, the averaged thresholds were (median/interquartile range): cerebral blood flow 21.7 mL/100 g/min (19.9 to 32); cerebral blood volume 1.5 mL/100 g (0.9 to 1.8); mean transit time seconds 5.2 (3.9 to 6.9); and relative time to peak 4.2 seconds (2.8 to 5.8). The large individual variability was best explained by the mean value of the hemispheric reference derived from a region of interest on a level with the basal ganglia of the unaffected hemisphere (R(2): cerebral blood flow 0.76, cerebral blood volume 0.55, mean transit time 0.83, time to peak 0.95). Hemispheric reference-corrected thresholds clearly improved the detection of penumbral flow. Look-up tables were calculated to identify the individual thresholds according to the hemispheric reference value.

CONCLUSIONS: The individual variation of PW values, even if calculated by deconvolution, remains a major obstacle in quantitative PW imaging and can be significantly improved by a simple MR-based calibration. Easily applicable look-up tables identify the individual best threshold for each PW map to optimize mismatch detection.

Share and Enjoy:
  • Digg
  • del.icio.us
  • Facebook
  • NewsVine
  • Reddit
  • StumbleUpon
  • Google Bookmarks
  • Yahoo! Buzz
  • Twitter
  • Technorati
  • Live
  • LinkedIn
  • MySpace

Related posts:

  1. Insights into schizophrenia using positron emission tomography: building the evidence and refining the focus.
  2. Advantages of Extended Brain Perfusion Computed Tomography: 9.6 cm Coverage With Time Resolved Computed Tomography-Angiography in Comparison to Standard Stroke-Computed Tomography.
  3. Single photon emission computed tomography (SPECT) imaging of the dopamine transporter in healthy dogs.
  4. Early detection of cardiac involvement in Miyoshi myopathy: 2D strain echocardiography and late gadolinium enhancement cardiovascular magnetic resonance.
  5. Positron Emission Tomography in Diagnosis and Differential Diagnosis of Parkinson’s Disease.
Tags:

Leave a Reply